UNIT WITH BUILT-IN COLD CARBONATOR (CONTāD)
Trouble Probable Cause Remedy
NO PRODUCT DISPENSED
FROM ALL DISPENSING
VALVES. (contād)
C. No electrical power to Unit. C. Plug in Unit power cord or check
for blown power fuse or tripped
circuit breaker.
D. Inoperative power switch (if
applicable).
D. Replace power switch.
E. Dispensing valves power cord
disconnected.
E. Connect dispensing valves power
cord.
F. Disconnected or broken wiring
to dispensing valve.
F. Connect or replace wiring.
G. Inoperative transformer or
valve solenoids.
G. Replace inoperative part.
ONLY CARBONATED WATER
DISPENSED.
A. Out of syrup. A. Replenish syrup supply as
instructed.
B. Inoperable dispensing valve. B. Repair dispensing valve.
C. Dispensing valve syrup flow
control not properly adjusted.
C. Adjust dispensing valve syrup
flow control as instructed.
D. Dispensing valve syrup flow
control or syrup lines
restricted.
D. Sanitize syrup system as
instructed.
ONLY SYRUP DISPENSED. A. Water inlet supply line shutoff
valve closed.
A. Open water inlet supply line
shutoff valve.
B. Carbonator power cord (under
hood) unplugged.
B. Remove hood and plug in
carbonator power cord.
C. Carbonator CO
2
regulator not
properly adjusted.
C. Adjust carbonator CO
2
regulator
as instructed.
D. Inoperative carbonator liquid
level control assembly.
D. Replace carbonator liquid level
control assembly.
E. Inoperative water pump, water
pump motor, or water pump
power switch.
E. Replace inoperative component.