52
318832000
REFRIGERATION SYSTEM (CONTD)
Trouble Probable Cause Remedy
AGITATOR MOTOR NOT
OPERATING. (contd)
C. No power source (blown fuse
or tripped circuit breaker).
C. Replace fuse or reset circuit
breaker. (NOTE: Fuse or circuit
breaker are not part of Unit).
D. Agitator motor propeller
obstructed.
D. Remove obstruction.
E. Low voltage. E. Voltage must be at least 103 volts
(115 VAC unit) or 208 (230 VAC
unit) at compressor terminals
when compressor is trying to
start.
F. Loose, disconnected, or
broken wiring.
F. Tighten connections or replace
broken wiring.
G. Inoperative agitator motor. G. Replace agitator motor.