EasyManuals Logo

Crestron Prodigy System User Manual

Crestron Prodigy System
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #92 background imageLoading...
Page #92 background image
Prodigy
®
System Crestron Mobile Pro App / XPanel for Mac
To select another zone, touch Room Select.
Temperature Control
A controlled climate zone uses setpoints to determine when the zone will be
heated or cooled. A zone may be configured to use only heating, cooling, or
a combination of both to maintain a temperature. Depending on the system
mode, a zone may use either one (single) or two (dual) setpoints to regulate
temperature.
Single Setpoint (available for Heat, Cool or Auto modes): When
using a single setpoint to regulate temperature, a single setpoint is
used for regulation at all times, regardless of whether the system is
heating or cooling.
NOTE: When using a single setpoint, the controlled zone has a
20-minute change limiter to prevent system toggling.
Dual Setpoints (for use in Auto mode only): When using dual
setpoints, separate heat and cool setpoints are used. When the
ambient temperature drops below the heat setpoint, the controlled
zone will call for heat to maintain the heat setpoint. When the
ambient temperature rises above the heat setpoint, the controlled
zone will not call for cooling until the temperature exceeds the cool
setpoint. When the ambient temperature drops below the cool
setpoint, the controlled zone will not call for heating until the
temperature is below the heat setpoint.
NOTE: When dual setpoints are used, the P-TSTATRF in the
controlled zone will display the setpoint closest to the ambient
temperature.
For instructions on setting the system mode, refer to “Set the System Mode”
on the following page.
86 Prodigy System: PMC2 System User Guide – DOC. 7007B

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Crestron Prodigy System and is the answer not in the manual?

Crestron Prodigy System Specifications

General IconGeneral
BrandCrestron
ModelProdigy System
CategoryControl Systems
LanguageEnglish

Related product manuals