10/2007 - Art. Nr. 13 017 700B 9
Start-up
Propane gas operation
NC12
NC16/NC21
Conversion natural gas Î propane
gas G31
Burner NC12
• Remove the combustion components
• Remove diffusor 3 and turbulator 4.
• Reassemble the turbulator without
the diffusor 3 while inserting closing
plate 5 (on the base plate) between
the turbulator and the star.
• Tighten the screws securely.
• Reinstall the combustion components.
Burner NC16/21
• Remove the combustion components
• Remove diffusor 3 and turbulator 4.
• Reassemble the turbulator and the
diffusor while inserting closing plate 5
(on the base plate) between the
turbulator and the star.
• Tighten the screws securely.
• Reinstall the combustion components.