3 Set-up and installation
Installation and operating manual
12
Daikin Altherma EHS(X/H)(B)-D
Daikin Altherma 3 R ECHO
008.1451099_00 – 07/2020
Dimensions …04P50D…/…08P50D…
 3‒2 Dimensions …04P50D…/…08P50D…
a Solar flow
b Domestic cold water
c Hot water
d Heating flow
e Heating return flow
f Connection for refrigerant gas line
g Connection for refrigerant fluid line
h Biv flow (…Biv type only)
i Biv return flow (…Biv type only)
A front
B rear
3.2 Transport and delivery
WARNING
When unfilled, the indoor unit is top-heavy and could tip
over during transport, which could put persons in danger or
damage the device.
Secure the indoor unit well, transport carefully, use the
handles.
The indoor unit is delivered on a pallet. All industrial trucks, such as
lifting trucks and forklift trucks, are suitable for transport.
Scope of delivery
Indoor unit (pre-mounted),
Bag of accessories,
Document pack.
 3‒3 Scope of delivery
a Handles (only required for transport)
b Cover screen
c Hose connecting piece for safety overflow
d Fitting spanner
e Ball valve
f Flat gasket
g O‑ring
h Cable tie
i Securing clip
j Venting hose
k Condensate drain hose
l Controller rotary switch
m Hood screws
n Document pack
For further accessories for the indoor unit, see price list.
3.3 Installing the heat pump
3.3.1 Selecting the installation site
CAUTION
If the total refrigerant charge in the system is ≥1.84kg, it is
essential to comply with additional requirements for
minimum footprint and minimum ventilation openings.
Observe "6.4 Minimum floor area and ventilation
openings"[434].
Information on the total refrigerant charge can be found on
the type plate of the outdoor unit. Please follow the
installation instructions.
The installation site of the indoor unit must meet the minimum
requirements below (see also "1.2.3Installation room"[45]).