 3‒10 Open the switch box
3 Hook in the cover on the switch box with the lateral hooks.
 3‒11 Hooking in the cover
3.4.5 Removing the bottom thermal insulation
CAUTION
The thermal insulation consists of pressure-sensitive EPP
moulded parts that can be easily damaged if not handled
correctly.
Only remove the thermal insulation in the order stated
below and in the stated directions.
Do not use force.
Do not use tools.
1 Remove the thermal insulation in the following order:
Pull the side insulating element off horizontally (itema).
Pull the rear insulating element off horizontally (itemb).
Pull the front insulating element off horizontally (itemc).
 3‒12 Removing the top thermal insulation
a Side insulating element
b Rear insulating element
c Front insulating element
2 As required: Remove the bottom thermal insulation in the
following order:
Pull the side insulating element off vertically (itema).
Pull the rear insulating element off vertically (itemb).
 3‒13 Removing the bottom thermal insulation
a Side insulating element
b Rear insulating element
INFORMATION
The thermal insulation is installed in reverse order.
3.4.6 Opening the air purge valve
1 Removing the thermal insulation (see "3.4.5 Removing the
bottom thermal insulation"[415]).
2 Open the air purge valve on the pump by one turn.