EasyManua.ls Logo

Danfoss VLT AutomationDrive FC 302

Danfoss VLT AutomationDrive FC 302
722 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Option
Name
Description
[238]
RS flipflop 8
[239]
RS flipflop 9
[240]
SL digital output A
[241]
SL digital output B
[242]
SL digital output C
[243]
SL digital output D
[244]
SL digital output E
[245]
SL digital output F
Parameter 13-58 SL Controller 4 Action
Table 693: Parameter 13-58 SL Controller 4 Action
13-58 SL Controller 4 Action
Default value: Size related
Parameter type: Option, Array [20]
Setup: 2 setups
Conversion index: -
Data type: Uint8
Change during operation: True
Select the action corresponding to the SLC event. Actions are executed when the corresponding event (defined in parameter 13-57
SL Controller 4 Event) is evaluated as true.
Option
Name
Description
[0]
DISABLED
[1]
No action
[2]
Select set-up 1
Changes the active setup (parameter 0-10 Active Set-up) to 1. If the setup is changed, it merges
with other setup commands coming from either the digital inputs or via a fieldbus.
[3]
Select set-up 2
Changes the active setup (parameter 0-10 Active Set-up) to 2. If the setup is changed, it merges
with other setup commands coming from either the digital inputs or via a fieldbus.
[4]
Select set-up 3
Changes the active setup (parameter 0-10 Active Set-up) to 3. If the setup is changed, it merges
with other setup commands coming from either the digital inputs or via a fieldbus.
[5]
Select set-up 4
Changes the active setup (parameter 0-10 Active Set-up) to 4. If the setup is changed, it merges
with other setup commands coming from either the digital inputs or via a fieldbus.
[10]
Select preset ref 0
Selects preset reference 0. If the active preset reference is changed, it merges with other preset
reference commands coming from either the digital inputs or via a fieldbus.
[11]
Select preset ref 1
Selects preset reference 1. If the active preset reference is changed, it merges with other preset
reference commands coming from either the digital inputs or via a fieldbus.
[12]
Select preset ref 2
Selects preset reference 2. If the active preset reference is changed, it merges with other preset
reference commands coming from either the digital inputs or via a fieldbus.
[13]
Select preset ref 3
Selects preset reference 3. If the active preset reference is changed, it merges with other preset
reference commands coming from either the digital inputs or via a fieldbus.
[14]
Select preset ref 4
Selects preset reference 4. If the active preset reference is changed, it merges with other preset
reference commands coming from either the digital inputs or via a fieldbus.
AU275636650261en-000101 / 130R0334442 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 302

Related product manuals