Parameter 43-14 PC Fan B Speed
Table 1417: Parameter 43-14 PC Fan B Speed
43-14 PC Fan B Speed
Default value: 0 RPM
Parameter type: Range, 0 - 65535, Array [8]
Setup: All set-ups
Conversion index: 67
Data type: Uint16
Change during operation: True
Shows the measured speed of fan B on the power card. Each power card has up to 3 fan connections. Place the fan in the drive
according to the Operating Guide. A typical placement for fan B is on the enclosure door (the internal fan). The value of this parame-
ter is:
The actual fan speed when there is a DC fan in the drive.
Relative speed when there is an AC fan in the drive.
Parameter 43-15 PC Fan C Speed
Table 1418: Parameter 43-15 PC Fan C Speed
43-15 PC Fan C Speed
Default value: 0 RPM
Parameter type: Range, 0 - 65535, Array [8]
Setup: All set-ups
Conversion index: 67
Data type: Uint16
Change during operation: True
Shows the measured speed of fan C on the power card. Each power card has up to 3 fan connections. Place the fan in the drive
according to the Operating Guide. A typical placement for fan C is inside the enclosure (the mixing fan). The value of this parameter
is:
The actual fan speed when there is a DC fan in the drive.
Relative speed when there is an AC fan in the drive.
5.32.3 43-2* Fan Pow.Card Status
N O T I C E
This parameter group is only available in FC 302.
Parameter 43-20 FPC Fan A Speed
Table 1419: Parameter 43-20 FPC Fan A Speed
43-20 FPC Fan A Speed
Default value: 0 RPM
Parameter type: Range, 0 - 65535, Array [2]
Setup: All set-ups
Conversion index: 67
Data type: Uint16
Change during operation: True
Shows the speed of the power card fan A.
Parameter 43-21 FPC Fan B Speed
Table 1420: Parameter 43-21 FPC Fan B Speed
43-21 FPC Fan B Speed
Default value: 0 RPM
Parameter type: Range, 0 - 65535, Array [2]
Setup: All set-ups
Conversion index: 67
Data type: Uint16
Change during operation: True
Shows the speed of the power card fan B.
AU275636650261en-000101 / 130R0334680 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 302 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 302
CategoryDC Drives
LanguageEnglish

Related product manuals