Parameter 17-83 Homing Speed
Table 953: Parameter 17-83 Homing Speed
17-83 Homing Speed
Default value: 150 RPM
Parameter type: Range, -32000 - 32000 RPM
Setup: All setups
Conversion index: 67
Data type: Int16
Change during operation: True
N O T I C E
This parameter is only available with software version 48.XX.
Enter the speed for the homing functions (parameter 17-80 Homing Function, options [10]–[13]).
Parameter 17-84 Homing Torque Limit
Table 954: Parameter 17-84 Homing Torque Limit
17-84 Homing Torque Limit
Default value: 160%
Parameter type: Range, -0 - 500%
Setup: All setups
Conversion index: 0
Data type: Uint16
Change during operation: True
N O T I C E
This parameter is only available with software version 48.XX.
Enter the torque limit for the homing functions (parameter 17-80 Homing Function, options [10]–[13]).
Parameter 17-85 Homing Timeout
Table 955: Parameter 17-85 Homing Timeout
17-85 Homing Timeout
Default value: 60.0 s
Parameter type: Range, -0.1 - 6000.0 s
Setup: All setups
Conversion index: -1
Data type: Uint16
Change during operation: True
N O T I C E
This parameter is only available with software version 48.XX.
Enter the timeout for the homing functions (parameter 17-80 Homing Function, options [10]–[13]). If the drive does not detect the
homing sensor or does not reach the torque limit within the timeout time, it aborts the homing process and trips.
Parameter 17-86 Homing Flag Behavior
Table 956: Parameter 17-86 Homing Flag Behavior
17-86 Homing Flag Behavior
Default value: [0] Clear at power-up
Parameter type: Option
Setup: All setups
Conversion index: -
Data type: Uint8
Change during operation: False
N O T I C E
This parameter is only available with software version 48.XX.
Select when the Homing OK signal is cleared.
AU275636650261en-000101 / 130R0334532 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 302 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 302
CategoryDC Drives
LanguageEnglish

Related product manuals