the other direction and repeats the current integration. On comparing the 2 integrated currents, the lift evacuates in the direction
which requires the least current.
Parameter 30-25 Measurement Duration
Table 1082: Parameter 30-25 Measurement Duration
30-25 Measurement Duration
Default value: 0.000 s
Parameter type: Range, 0.000 - 10.000 s
Setup: All setups
Conversion index: -3
Data type: Uint32
Change during operation: True
Duration of current integration measurement. The measurement is done in both directions. The direction with the lowest measure-
ment value is selected by the drive.
Parameter 30-26 Delay Before Measurements
Table 1083: Parameter 30-26 Delay Before Measurements
30-26 Delay Before Measurements
Default value: 0.000 s
Parameter type: Range, 0.000 - 10.000 s
Setup: All setups
Conversion index: 0
Data type: Uint16
Change during operation: True
Delay before current measurement. Allows to avoid mismatch in measurements caused by mechanical friction during opening of
mechanical brakes.
Parameter 30-27 Light Load Speed [%]
Table 1084: Parameter 30-27 Light Load Speed [%]
30-27 Light Load Speed [%]
Default value: 0%
Parameter type: Range, 0 - 100%
Setup: All setups
Conversion index: 0
Data type: Uint16
Change during operation: True
Use this parameter when the light-load detection is active to define the speed during current measurement. Enter the reference
speed during the light-load detection. The value is a percentage of nominal motor speed in parameter 1-25 Motor Nominal Speed.
For standard asynchronous motors, the synchronous speed is used instead of parameter 1-25 Motor Nominal Speed due to slip.
Parameter 30-28 Evacuation Speed [%]
Table 1085: Parameter 30-28 Evacuation Speed [%]
30-28 Evacuation Speed [%]
Default value: 0%
Parameter type: Range, 0 - 100%
Setup: All setups
Conversion index: 0
Data type: Uint16
Change during operation: True
Speed for evacuation after detection of light-load direction.
Parameter 30-29 Ramp Time
Table 1086: Parameter 30-29 Ramp Time
30-29 Ramp Time
Default value: Size related
Parameter type: Range, 0.01 - 3600 s
Setup: All setups
Conversion index: -2
Data type: Uint32
Change during operation: True
Ramp times during evacuation and measurement sequences.
AU275636650261en-000101 / 130R0334 | 581Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 302 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 302
CategoryDC Drives
LanguageEnglish

Related product manuals