AutomationDrive FC 301/FC 302 - Mains: 200-240V (T2) - 40% Duty Cycle
AutomationDrive FC
301/FC 302
P
m (HO)
R
min
R
br, nom
R
rec
P
br avg
Order
no.
Period Cable cross
section
Therm.
relay
Max. brake
torque with
R
rec
*
T2 [kW]
[Ω] [Ω] [Ω]
[kW] 175Uxxxx [s] [mm2] [A] [%]
P5K5 5.5 18 20 20 3.5 1926 120 1.5 13 (160)
P7K5 7.5 13 14 15 5 1927 120 2.5 18 (160)
P11K 11 9 10 10 9 1928 120 10 30 (160)
P15K 15 6 7 7 10 1929 120 16 38 (150)
P18K 18.5 5.1 6 6 12.7 1930 120 16 46 (150)
P22K 22 4.2 5 (150)
P30K 30 3 3.7 (150)
P37K 37 2.4 3 (150)
FC 301 - Mains: 380-480V (T4) - 40% Duty Cycle
FC 301 P
m (HO)
R
min
R
br, nom
R
rec
P
br avg
Order no. Period Cable
cross
section
2
*
Therm.
relay
Max. brake
torque with
R
rec
*
T4 [kW]
[Ω] [Ω] [Ω]
[kW] 175Uxxxx [s] [mm2] [A] [%]
PK37 0.37 620 1098 620 0.26 1940 120 1.5 0.6 160 (160)
PK55 0.55 620 739 620 0.26 1940 120 1.5 0.6 160 (160)
PK75 0.75 485 539 620 0.26 1940 120 1.5 0.6 139 (160)
P1K1 1.1 329 366 425 0.43 1941 120 1.5 1 138 (160)
P1K5 1.5 240 267 310 0.80 1942 120 1.5 1.6 138 (160)
P2K2 2.2 161 179 210 1.35 1943 120 1.5 2.5 137 (160)
P3K0 3 117 130 150 2.00 1944 120 1.5 3.7 139 (160)
P4K0 4 87 97 110 2.40 1945 120 1.5 4.7 140 (160)
P5K5 5.5 63 69 80 3.00 1946 120 1.5 6.1 139 (160)
P7K5 7.5 45 50 65 4.50 1947 120 1.5 8.3 124 (160)
P11K 11 34.9 38.8 40 5.00 1948 120 1.5 11 155 (160)
P15K 15 25.3 28.1 30 9.30 1949 120 2.5 18 150 (160)
P18K 18.5 20.3 22.6 25 12.70 1950 120 4 23 144 (160)
P22K 22 16.9 18.8 20 13.00 1951 120 4 25 150 (160)
P30K 30 13.2 14.7 15 15.60 1952 120 10 32 147 (150)
P37K 37 10.6 12 12 19.00 1953 120 10 40 147 (150)
P45K 45 8.7 10 9.8 38.00 2007 120 16 62 148 (150)
P55K 55 6.6 8 7.3 38.00 0068 120 25 72 150 (150)
P55K 55 6.6 7.9 5.7 150 (150)
P75K 75 6.6 5.7 6.3 45.00 0066 120 25 87 150 (150)
P75K 75 4.2 5.7 4.7 150 (150)
P75K 75 4.2 5.7 4.7 150 (150)
How to Order FC 300 Design Guide
MG.33.BD.02 - VLT
®
is a registered Danfoss trademark 107
5 5