6-180 Magellan
®
8100/8100Ω and 8200/8200Ω Scanner
RSS Expanded Fixed Length 2
This feature specifies RSS Expanded second fixed length.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code, SET RSS EXPANDED FIXED LENGTH 2
below. You’ll need to cover any unused bar codes on this and the
facing page to ensure that the scanner reads only the bar code you
intend to scan.
3. Scan the appropriate digits from the keypad in Appendix C that
represent the desired fixed label length. The selectable range for
this option is 00 to 74. Pad all single digit numbers with a leading
zero to yield a two-digit entry (00-74).
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET RSS EXPANDED FIXED LENGTH 2
NOTE
This applies when RSS Expanded Length Control is set to fixed-
length decoding.
If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply.