Product Reference Guide 6-261
Standard 2 of 5 Check Character Transmission
Enables/disables transmission of an optional Standard 2 of 5 check charac-
ter.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan either the enable or disable bar code below. You’ll need to cover
any unused bar codes on this and the facing page to ensure that the
scanner reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the SWITCH
bar code.
STANDARD 2 of 5 CHECK CHARACTER TRANSMISSION = DISABLE
STANDARD 2 of 5 CHECK CHARACTER TRANSMISSION = ENABLE
NOTE
This feature applies only when Standard 2 of 5 Check Charac-
ter Calculation is enabled. This item is ignored when the advanced
feature, Full Label Edit, is enabled.