EasyManuals Logo

Datalogic MAGELLAN 8100 User Manual

Datalogic MAGELLAN 8100
440 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #372 background imageLoading...
Page #372 background image
6-264 Magellan
®
8100/8100Ω and 8200/8200Ω Scanner
Standard 2 of 5 Length Control
This feature specifies whether variable-length or fixed-length decoding
will be set for
Standard 2 of 5.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan your selection from the bar codes below. You’ll need to cover
any unused bar codes on this and the facing page to ensure that the
scanner reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the SWITCH
bar code.
STANDARD 2 OF 5 LENGTH CONTROL = VARIABLE-LENGTH
STANDARD 2 OF 5 LENGTH CONTROL = FIXED-LENGTH
NOTE
If variable-length control was selected, you must now set the features
Standard 2 of 5 Maximum Label Length and Standard 2 of 5
Minimum Label Length. If fixed-length control was selected, you
must now set Standard 2 of 5 Fixed Length 1 and Standard 2
of 5 Fixed Length 2.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic MAGELLAN 8100 and is the answer not in the manual?

Datalogic MAGELLAN 8100 Specifications

General IconGeneral
BrandDatalogic
ModelMAGELLAN 8100
CategoryBarcode Reader
LanguageEnglish

Related product manuals