8100/8100Ω and 8200/8200Ω Scanner
Pharmacode 39 Check Character Transmission
Enables/disables transmission of Pharmacode 39 check character.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan either the enable or disable bar code below. You’ll need to
cover any unused bar codes on this and the facing page to ensure
that the scanner reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the SWITCH
bar code.
PHARMACODE 39 CHECK CHARACTER TRANSMISSION = DISABLE
PHARMACODE 39 CHECK CHARACTER TRANSMISSION = ENABLE
NOTE
This item is ignored when the advanced feature, Full Label Edit, is enabled.