Wireless Features
Product Reference Guide
311
STAR Radio Protocol Timeout
This parameter sets the valid wait time before transmission between the
handheld reader and Base Station is considered failed.
When setting this parameter, take into
consideration the radio traffic (num-
ber of readers in the same area). The selectable range for this feature is from
02
to 25 seconds.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield two digits. For example: 2
= 02, 5 = 05, 25
= 25, etc
3. Go to page 247 and scanScan the ENTER/EXIT PROGRAMMING MODE
barcode to enter Programming Mode.
4. Scan the barcode: SELECT RADIO PROTOCOL TIMEOUT.
5. Scan the appropriate two digits from the keypad in Appendix D, Key-
pad, that represent the duration which was determined in the steps
above. You will hear a two-beep indic
ation after the last character.
If you make a mistake before the last character, scan the CANCEL bar-
code to abort and not save the entry string. You can then start again
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
ming Mode.
This completes the procedure. See Table 46 for some examples of how to
set this feature.
Table 46. STAR Radio Protocol Timeout Examples
STEP ACTION EXAMPLES
1 Desired Setting
2 Seconds 5 Seconds 10 Seconds 25 Seconds
2 Pad with leading zero(es)
02 05 10 25
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECTSTAR RADIO PROTOCOL TIMEOUT SETTING
5
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘2’ ‘0’ and ‘5’ ‘1’ and ‘0’ ‘2’ AND ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PBT9100 and is the answer not in the manual?

Datalogic PowerScan PBT9100 Specifications

General IconGeneral
Harmonized System (HS) code84716070
TypeHandheld bar code reader
Sensor typeLED
Scanner type1D
Yaw reading angle-70 - 70 °
Scanner resolution0.13 mm
Tilt reading angle-45 - 45 °
Pitch reading angle-75 - 75 °
Linear (1D) barcodes supportedCodabar, Code 11, Code 128, Code 32, Code 39, Code 39 (ASCII), Code 93, EAN 128, GS1 DataBar, IATA, ISBN, Industrial 2 of 5, Interleaved 2 of 5, MSI, Plessey, UPC-A, UPC-E
2D (matrix & stacked) barcodes supported-
Wireless range100 m
Bluetooth version3.0
Operating frequency2.4-2480 MHz
Standard interfacesBluetooth, RS-232
Connectivity technologyWireless
CertificationIEC 62471
Product colorBlack, Yellow
LED indicatorsYes
International Protection (IP) codeIP65
Battery life10 h
Battery typeBuilt-in battery
Charging time4.5 h
Input voltage10-30 V
Battery capacity3350 mAh
Power consumption500 mA
Power source typeBattery
AC adapter output voltage110 V
Number of reads per charge60000
Power consumption (typical)10 W
Cables includedDC, RS-232
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-20 - 50 °C
Operating relative humidity (H-H)5 - 95 %
Warranty period3 year(s)
Sustainability certificatesRoHS
Weight and Dimensions IconWeight and Dimensions
Depth74 mm
Width110 mm
Height240 mm
Weight405 g
Base dimensions212 x 110 x 74 mm