I 2 of 5 Check Character Transmission .................................................................................................................................... 123
I 2 of 5 Minimum Reads ............................................................................................................................................................ 123
I 2 of 5 Decoding Levels ............................................................................................................................................................ 124
I 2 of 5 Length Control .............................................................................................................................................................. 125
I 2 of 5 Set Length 1 .................................................................................................................................................................. 126
I 2 of 5 Set Length 2 .................................................................................................................................................................. 127
I 2 of 5 Zero Pattern .................................................................................................................................................................. 128
INTERLEAVED 2 OF 5 CIP HR ............................................................................................................................................................ 129
Interleaved 2 of 5 Enable/Disable .......................................................................................................................................... 129
DATALOGIC 2 OF 5 .............................................................................................................................................................................. 130
Datalogic 2 of 5 Enable/Disable .............................................................................................................................................. 130
Datalogic 2 of 5 Check Character Calculation ......................................................................................................................... 130
Datalogic 2 of 5 Check Character Transmission ..................................................................................................................... 131
Datalogic 2 of 5 Minimum Reads ............................................................................................................................................ 131
Datalogic 2 of 5 Decoding Levels ............................................................................................................................................. 131
Datalogic 2 of 5 Length Control ............................................................................................................................................... 132
Datalogic 2 of 5 Set Length 1 ................................................................................................................................................... 132
Datalogic 2 of 5 Set Length 2 ................................................................................................................................................... 133
Datalogic 2 of 5 Interdigit Maximum Ratio ............................................................................................................................. 134
FOLLETT 2 OF 5 (ONLY STANDARD OPTIC MODELS) ...................................................................................................................... 135
Follett 2 of 5 Enable/Disable ................................................................................................................................................... 135
STANDARD 2 OF 5 .............................................................................................................................................................................. 136
Standard 2 of 5 Enable/Disable .............................................................................................................................................. 136
Standard 2 of 5 Check Character Calculation ......................................................................................................................... 136
Standard 2 of 5 Check Character Transmission ..................................................................................................................... 137
Standard 2 of 5 Minimum Reads ............................................................................................................................................. 137
Standard 2 of 5 Decoding Levels ............................................................................................................................................. 138
Standard 2 of 5 Length Control ............................................................................................................................................... 138
Standard 2 of 5 Set Length 1 ................................................................................................................................................... 139
Standard 2 of 5 Set Length 2 ................................................................................................................................................... 140
INDUSTRIAL 2 OF 5 (ONLY STANDARD OPTIC MODELS) ................................................................................................................ 141
Industrial 2 of 5 Enable/Disable .............................................................................................................................................. 141
Industrial 2 of 5 Check Character Calculation ........................................................................................................................ 141
Industrial 2 of 5 Check Character Transmission .................................................................................................................... 142
Industrial 2 of 5 Length Control ............................................................................................................................................... 142
Industrial 2 of 5 Set Length 1 ................................................................................................................................................... 143
Industrial 2 of 5 Set Length 2 ................................................................................................................................................... 144
Industrial 2 of 5 Minimum Reads ............................................................................................................................................ 145
CODE IATA (ONLY STANDARD OPTIC MODELS) ............................................................................................................................... 146
IATA Enable/Disable ................................................................................................................................................................. 146
IATA Check Character Transmission ....................................................................................................................................... 146
CODABAR ............................................................................................................................................................................................ 147
Codabar Enable/Disable ........................................................................................................................................................... 147
Codabar Check Character Calculation ..................................................................................................................................... 147
Codabar Check Character Transmission ................................................................................................................................. 148
Codabar Start/Stop Character Transmission ......................................................................................................................... 148
Codabar Start/Stop Character Set .......................................................................................................................................... 149
Codabar Start/Stop Character Match ..................................................................................................................................... 149
Codabar Quiet Zones ................................................................................................................................................................ 150
Codabar Minimum Reads ......................................................................................................................................................... 151
Codabar Decoding Levels ......................................................................................................................................................... 152
Codabar Length Control ............................................................................................................................................................ 153
Codabar Set Length 1 ................................................................................................................................................................ 154
Codabar Set Length 2 ................................................................................................................................................................ 155
Codabar Interdigit Ratio ........................................................................................................................................................... 156
ABC CODABAR .................................................................................................................................................................................... 158
ABC Codabar Enable/Disable ................................................................................................................................................... 158
ABC Codabar Concatenation Mode .......................................................................................................................................... 158
ABC Codabar Dynamic Concatenation Timeout ..................................................................................................................... 159
ABC Codabar Force Concatenation .......................................................................................................................................... 159
CODE 11 (ONLY STANDARD OPTIC MODELS) .................................................................................................................................. 160
Code 11 Enable/Disable ........................................................................................................................................................... 160
Code 11 Check Character Calculation ...................................................................................................................................... 160
Code 11 Check Character Transmission .................................................................................................................................. 161
Code 11 Minimum Reads ......................................................................................................................................................... 161
Code 11 Length Control ............................................................................................................................................................ 162
Code 11 Set Length 1 ................................................................................................................................................................ 163

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PBT9100 and is the answer not in the manual?

Datalogic PowerScan PBT9100 Specifications

General IconGeneral
Harmonized System (HS) code84716070
TypeHandheld bar code reader
Sensor typeLED
Scanner type1D
Yaw reading angle-70 - 70 °
Scanner resolution0.13 mm
Tilt reading angle-45 - 45 °
Pitch reading angle-75 - 75 °
Linear (1D) barcodes supportedCodabar, Code 11, Code 128, Code 32, Code 39, Code 39 (ASCII), Code 93, EAN 128, GS1 DataBar, IATA, ISBN, Industrial 2 of 5, Interleaved 2 of 5, MSI, Plessey, UPC-A, UPC-E
2D (matrix & stacked) barcodes supported-
Wireless range100 m
Bluetooth version3.0
Operating frequency2.4-2480 MHz
Standard interfacesBluetooth, RS-232
Connectivity technologyWireless
CertificationIEC 62471
Product colorBlack, Yellow
LED indicatorsYes
International Protection (IP) codeIP65
Battery life10 h
Battery typeBuilt-in battery
Charging time4.5 h
Input voltage10-30 V
Battery capacity3350 mAh
Power consumption500 mA
Power source typeBattery
AC adapter output voltage110 V
Number of reads per charge60000
Power consumption (typical)10 W
Cables includedDC, RS-232
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-20 - 50 °C
Operating relative humidity (H-H)5 - 95 %
Warranty period3 year(s)
Sustainability certificatesRoHS
Weight and Dimensions IconWeight and Dimensions
Depth74 mm
Width110 mm
Height240 mm
Weight405 g
Base dimensions212 x 110 x 74 mm