76
PowerScan™ PD9130/PBT9100/PM9100
Default settings are indicated at each feature/option with a green arrow.
Also reference Appendix C, Standard Defaults for a listing of the most widely
used set of standard factory settings.
That section also provides space to
record any custom settings needed or implemented for your system.
To set most features:
1. Scan the ENTER/EXIT PROGRAMMING bar co
de at the top of applicable
programming pages.
2. Scan the correct bar code to set th
e desired programming feature or
parameter. You may need to cover unused bar codes on the page, and
possibly the facing page, to ensure that the reader reads only the bar
code you intend to scan.
3. If additional input parame
ters are needed, go to Appendix D, Keypad,
and scan the appropriate characters from the keypad.
Additional information about many features can be found in the
“References” chapter.
If you make a mistake before the la
st character, scan the CANCEL
bar code to abort and not save the entry string. You can then start
again at the beginning.
4. Complete the programming sequence by scanning the ENTER/EXIT
PROGRAMMING bar code to exit Programming Mode.
GS1 DATABAR™ EXPANDED on page 170
GS1 DATABAR™ LIMITED on page 175
CODE 93 on page 177
CODABLOCK F on page 184
CODE 4 on page 188
CODE 5 on page 190
CODE 4 AND CODE 5 COMMON CONFIGURATION ITEMS on page 192
BC412 on page 194
MSI on page 200
PLESSEY (ONLY STANDARD OPTIC MODELS) on page 206

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PBT9100 and is the answer not in the manual?

Datalogic PowerScan PBT9100 Specifications

General IconGeneral
Harmonized System (HS) code84716070
TypeHandheld bar code reader
Sensor typeLED
Scanner type1D
Yaw reading angle-70 - 70 °
Scanner resolution0.13 mm
Tilt reading angle-45 - 45 °
Pitch reading angle-75 - 75 °
Linear (1D) barcodes supportedCodabar, Code 11, Code 128, Code 32, Code 39, Code 39 (ASCII), Code 93, EAN 128, GS1 DataBar, IATA, ISBN, Industrial 2 of 5, Interleaved 2 of 5, MSI, Plessey, UPC-A, UPC-E
2D (matrix & stacked) barcodes supported-
Wireless range100 m
Bluetooth version3.0
Operating frequency2.4-2480 MHz
Standard interfacesBluetooth, RS-232
Connectivity technologyWireless
CertificationIEC 62471
Product colorBlack, Yellow
LED indicatorsYes
International Protection (IP) codeIP65
Battery life10 h
Battery typeBuilt-in battery
Charging time4.5 h
Input voltage10-30 V
Battery capacity3350 mAh
Power consumption500 mA
Power source typeBattery
AC adapter output voltage110 V
Number of reads per charge60000
Power consumption (typical)10 W
Cables includedDC, RS-232
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-20 - 50 °C
Operating relative humidity (H-H)5 - 95 %
Warranty period3 year(s)
Sustainability certificatesRoHS
Weight and Dimensions IconWeight and Dimensions
Depth74 mm
Width110 mm
Height240 mm
Weight405 g
Base dimensions212 x 110 x 74 mm