CODE 39 ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
87
CODE 39
The following options apply to the Code 39 symbology.
Code 39 Enable/Disable
When disabled, the scanner will not read Code 39 bar codes.
Code 39 Check Character Calculation
Enable this option to enable/disable calculation and verification of an optional Code 39
check character. When disabled, any check character in the label is treated as a data
character.
$CC3EN00
Code 39 = Disable
Code 39 = Enable
$CC3EN01
$CC3CC00
Code 39 Check Character Calculation =
Don’t Calculate
Code 39 Check Character Calculation = Calculate Std Check
$CC3CC01
$CC3CC02
Code 39 Check Character Calculation
= Calculate Mod 7 Check
Code 39 Check Character Calculation
= Enable Italian Post Check
$CC3CC04