EasyManua.ls Logo

Dell EMC PowerEdge R7425 - Air Shroud; Removing the Air Shroud

Dell EMC PowerEdge R7425
193 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 27. Inside the system – Con
guration showing mid drive tray and rear drive cage
1 backplane 2 backplane expander
3 cooling fan (6) in the cooling fan assembly 4 drive (4) in the mid drive tray
5 mid drive backplane 6 rear drive backplane
7 drive (2 x 3.5 inch or 4 x 2.5 inch) in the rear drive cage 8 system board
9 riser 1
Air shroud
The air shroud directs the airo
w across the entire system. Air shroud prevents the system from overheating and is used to maintain
uniform airow inside the system.
Removing the air shroud
Prerequisites
CAUTION: Never operate your system with the air shroud removed. The system may get overheated quickly, resulting in
shutdown of the system and loss of data.
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 If installed, remove the expansion cards.
Step
Hold the air shroud at both ends and lift it away from the system.
Installing and removing system components 71

Table of Contents

Other manuals for Dell EMC PowerEdge R7425

Related product manuals