Advanced Features 63
3 Using the arrow keys, select Activate/Delete RAID Array and press <Enter>.
4 Press any key to continue.
5 Use the <Page Up> or the <Page Down> keys to select the volume to be activated.
6 Press <F2> to return to the top menu.
7 Select Activate Array and press <Enter>.
8 Press any key to continue.
While the configuration utility activates the stripe volume and deactivates the other
stripe volumes, the following message appears:
Processing...takes upto one
minute
. The main menu appears once the stripe volume is activated.
NOTE: If a partial stripe volume is present and no longer part of a good array, the partial stripe
volume can be deleted, see "Deleting a Stripe Volume."
Troubleshooting the Stripe Volume
DURING INSTALLATION, NO SCSI DRIVES ARE FOUND —
• Ensure that all devices are connected.
• Ensure that each device has a unique SCSI ID, including the SCSI controller.
• Ensure that the SCSI controller is enabled in the system BIOS.
• Ensure that all devices can be seen in the Fusion-MPT SCSI BIOS display
banner when the computer starts up.
• Reset the Fusion-MPT SCSI BIOS setting to default.