11
1
Parameter name Function
Data
type
Valid range
(Default)
Validation timing
variations
GearRatioNumeratorM1
Specify the master
axis1 gear ratio
numerator.
LREAL
Positive number
or negative
number
(The variable
value must be
set)
When Execute
changes from FALSE
to TRUE
GearRatioDenominatorM1
Specify the master
axis1 gear ratio
denominator.
LREAL
Positive number
or negative
number
(The variable
value must be
set)
When Execute
changes from FALSE
to TRUE
GearRatioNumeratorM2
Specify the master
axis2 gear ratio
numerator.
LREAL
Positive number
or negative
number
(The variable
value must be
set)
When Execute
changes from FALSE
to TRUE
GearRatioDenominatorM2
Specify the master
axis2 gear ratio
denominator.
LREAL
Positive number
or negative
number
(The variable
value must be
set)
When Execute
changes from FALSE
to TRUE
MasterValueSourceM1
Specify the
synchronization
position source of
master axis 1.
0Command position
1Actual position
MC_SOU
RCE
0:mcSetValue
1:mcActualValue
(0)
When Execute
changes from FALSE
to TRUE
MasterValueSourceM2
Specify the
synchronization
position source of
master axis 2.
0Command position
1Actual position
MC_SOU
RCE
0:mcSetValue
1:mcActualValue
(0)
When Execute
changes from FALSE
to TRUE
Acc
Specify the
acceleration for the
slave axis.
LREAL
Positive number
(The variable
value must be
set)
When Execute
changes from FALSE
to TRUE
Dec
Specify the
deceleration for the
slave axis.
LREAL
Positive number
(The variable
value must be
set)
When Execute
changes from FALSE
to TRUE
Jerk
Specify the change
rate of the
acceleration for the
slave axis.
LREAL
Positive number
(The variable
value must be
set)
When Execute
changes from FALSE
to TRUE
11-140