DVP15MC11T Operation Manual
11
1
Output Update Timing
Name
Timing for changing to TRUE
Timing for changing to FALSE
Done
When the coupling between the
rotary-cut axis and feed axis is
completed.
When Execute changes from
TRUE to FALSE after the
instruction execution is completed.
Done changes to TRUE when the
instruction execution is completed
after Execute changes from TRUE
to FALSE during the instruction
execution. One cycle later, Done
changes to FALSE.
Busy When Execute changes to TRUE.
When Done changes to TRUE.
When Error changes to TRUE.
Error
When an error occurs in the
instruction execution or the input
parameters for the instruction are
illegal.
When Execute changes from
TRUE to FALSE.
Function
APF_RotaryCut_In is used for building a rotary cut relationship and specifying the axis No. of the
rotary-cut axis and feed axis according to the application requirement. The rotary cut axis will follow the
feed axis for motion based on the rotary-cut curve after the instruction execution succeeds.
11-186

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Electronics DVP15MC11T and is the answer not in the manual?

Delta Electronics DVP15MC11T Specifications

General IconGeneral
BrandDelta Electronics
ModelDVP15MC11T
CategoryController
LanguageEnglish

Related product manuals