EasyManuals Logo

Delta DVP-ES3 Series Hardware Manual

Delta DVP-ES3 Series
489 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #410 background imageLoading...
Page #410 background image
DVP-ES3/EX3/SV3/SX3 Series Hardware and Operation Manual
10-42
_10
7. Program explanation
When the DVP-ES3 Series PLC runs for the first time, set the parameter P3-06 for servo drive to F.
When M0 switches from OFF to ON, the instruction writes 256 to D25032 and then writes the value to
the servo parameter P1-09 through RxPDO1.
When M1 switches from OFF to ON, change P4-07 to 5. DI1 and DI3 are ON. DI1 means the SERVO is
ON and DI3 calls the speed specified by parameter P1-09 for servo rotation.
When M1 switches from ON to OFF, the speed command becomes 0 and the motor stops running.

Table of Contents

Other manuals for Delta DVP-ES3 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta DVP-ES3 Series and is the answer not in the manual?

Delta DVP-ES3 Series Specifications

General IconGeneral
BrandDelta
ModelDVP-ES3 Series
CategoryController
LanguageEnglish

Related product manuals