DVP-ES3/EX3/SV3/SX3 Series Hardware and Operation Manual
14-20
Error
code
Description
CPU
status
ERROR LED indicator status
ON
200B
The operand n or the other constant operands K/H
exceed the range.
Continue V
200D
The binary to binary-
coded decimal conversion is
incorrect.
Continue V
200E The string does not end with 00. Continue V
Incorrect division operation
2013
The value exceeds the range of values which can
be represented by the floating-point numbers.
Continue V
2014
The task designated by the TKON or YKOFF
instruction is incorrect, or exceeds the range.
Continue V
2017
The instruction BREAK is written outside of the
FOR-NEXT loop.
Continue V
2027
No such position planning table number or the
format is incorrect.
Continue V
2028
The high speed output instruction is being
executed. Only one instruction can be executed at a
time.
Continue V
The IP address filter is set incorrectly.
RJ45 port is not connected.
6010
The number of the MODBUS TCP connections
Continue V
6011
The number of the EtherNet/IP connections
exceeds the range.
Continue V
There are devices using the same IP address.
The email connection is busy.
6103
The trigger attachment mode in the email is set
incorrectly.
Continue V
The attachment in the email does not exist.
The attachment in the email is too big.
There is an SMTP server response timeout.
There is an SMTP server response timeout.
6200
The remote communication IP address set in the
TCP socket function is illegal.
Continue V
6201
The local communication port set in the TCP socket
function is illegal.
Continue V
6202
The remote communication port set in the TCP
socket function is illegal.
Continue V
6203
The device from which the data is
sent in the TCP
socket function is illegal.
Continue V
6206
The device that receives the data in the TCP socket
function is illegal.
Continue V
6208
The data that is received through the TCP socket
exceeds the device range.
Continue V