DVP-ES3/EX3/SV3/SX3 Series Hardware and Operation Manual
2-22
_2
Model
Item
DVP28SV311T
DVP28SV311R
DVP28SV311S
DVP20SX311T
DVP20SX311R
DVP20SX311S
Analog input mode N/A
-10V~10V; -20mA~20mA; 4mA~20mA;
channels closed
Analog linearity
deviation
N/A
Normal temperature environment:
±0.5%; All temperature environment:
±1.0%
Analog input
impedance
N/A
1MΩ (Voltage mode)
250Ω (Current mode)
Analog input isolation
When there is isolation between analog and digital electricals and there is no
isolation among analog channels.
Isolation between digital electrical and grounding: 500 VAC
Isolation between analog and digital electrical: 500 VAC
Isolation between analog electrical and grounding: 500 VAC
Isolation between 24 VDC and grounding: 500 VAC
*
1
: Analog input data updates automatically in every PLC scan cycle.