Delta VFD-B - Chapter 7 Troubleshooting; 7.1 Over Current (OC)

Delta VFD-B
239 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Revision July 2008, BE16, SW V4.08 & V5.00 7-1
Chapter 7 Troubleshooting
7.1 Over Current (OC)
ocA
ocd
OC
Ov er-curre nt
dur ing acceleration
Over- c ur rent
dur ing de cele ration
Ove r curren t
Check if there is any
betw een t he U, V, W and motor
sh ort c irc uits and
grounding
Ye s
No
No
No
No No
No
Ye s
Ye s
Yes
Remove short c ircuit
or ground fault
Reduce the load or
increase t he power
of AC motor drive
NoNo
Reduce torque
compen sation
Reduce tor que
compensation
Suitable torque
compensation
No No
No
No
No
Ye s
Yes
Ye s
Yes
Yes
Maybe AC motor drive
has malfunction or error
due to noise. Please
contact DELTA.
Can acceleration
time be made longe r?
Can dec elerati o n
time be made l o nger?
Reduce lo ad or in crease
the power of AC motor
drive
Check brake
method. Please
contact D ELTA
Reduce load or increase
the power of AC motor
drive
Has l oad cha nged
suddenly?
Check if
acceleration time
is too short by
load inertia.
Check if
dec eleration time
is too short by
loa d inertia.
Incre ase accel/decel
time
Check if load is too large