EasyManuals Logo

Delta VFD-B User Manual

Delta VFD-B
239 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #169 background imageLoading...
Page #169 background image
Chapter 7 Troubleshooting |VFD-B Series
7-2 Revision July 2008, BE16, SW V4.08 & V5.00
7.2 Ground Fault
GFF
Ground fault
No
Yes
Is output circuit(cable or
motor) of AC motor drive
grounded?
Remove ground fault
Maybe AC motor drive has
malfunction or misoperation
due to noise. Please
contact DELTA.
7.3 Over Voltage (OV)
Over voltage
Ye s
No
Ye s
No
No
No
Is voltage within
specification
Reduce voltage to
be within spec.
Has over-voltage occurred without load
Maybe AC motor drive
has malfunction or
misoperation due to
noise. Please contact
DELTA.
Ye s
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
When OV occurs, check if the
voltage of DC BUS is greater
than protection value
Dose OV occur when
sudden acceleration
stops
Increase
deceleration
time
Increase setting time
Increase
acceleration
time
Reduce moment
of inertia
Reduce moment of load inertia
Use brake unit or DC brake
Need to check control method. Please contact DELTA.
Need to consider using
brake unit or
DC brake

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD-B and is the answer not in the manual?

Delta VFD-B Specifications

General IconGeneral
SeriesVFD-B
Power Range0.4kW to 15kW
Control MethodV/F Control, Sensorless Vector Control
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
CommunicationRS-485
Protection FeaturesOver-voltage, Over-current, Overheat, Under-voltage, Ground fault, Short circuit

Related product manuals