Machine Installation & Operation
Adequate fall must be maintained for proper drainage.
Protective Film
The machine may have protective adhesive fi lm on the front escutcheon area and the front and
side stainless steel panels. The fi lm may be peeled off before putting the machine into service.
Electrical
Dexter single/three-phase 208-240VAC 60 Hz washing machines are intended to be permanently
installed appliances. No power cord is provided. The machine should be connected to an individ-
ual branch circuit not shared by lighting or other equipment. The connection should be sheathed in
liquid tight fl exible conduit, or equivalent, with conductors of the proper size and insulation. A quali-
ed technician should make such connections in accordance with the wiring diagram.
T-300 WCVD18HCS-10 model (1 phase 120 volts) washers are equipped with an electrical cord
with a 3 prong grounded plug. A U.L. approved receptacle, which has been properly grounded in
accordance with local electrical codes must be used with the machine. Each unit should be con-
nected to an individual branch circuit not shared by lighting or other equipment. Conductors of the
proper size and insulation (suggested size below) should be used.
To Make Electrical Connections
Disconnect all power to the washer. Remove screw and lift out the cover located in the upper left
corner of the machine (as viewed from the back).
• If power is 208-240-3PH-60Hz, connect L1, L2, L3 and ground. If there is a high leg it
must be connected to L3. It is highly recommended to use a TVSS. (See page 107.)
• If power is 208-240-1PH-60Hz, connect L1, L2 and Ground. If power is 120 -1PH-60Hz.
Use a UL approved receptacle with proper external ground.
NOTE: It is important that the grounding screw next to the power terminal block TB-1 be
connected to a good external ground.
Controls Transformer
The controls transformer is located inside the control trough and steps a range of 208 to 240 volts
down to 115 volts. There are two terminals on the controls transformer for the primary (incoming)
power. Use the terminal marked “208V” for power supplies between 200 and 215 volts. Use the
terminal marked “230V” for power supplies between 216 and 240 volts.
NOTE: TRANSFORMER MUST BE SET AT PROPER TAP FOR PROPER
OPERATION.
17

Table of Contents

Other manuals for Dexter Laundry A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dexter Laundry A Series and is the answer not in the manual?

Dexter Laundry A Series Specifications

General IconGeneral
BrandDexter Laundry
ModelA Series
CategoryWasher
LanguageEnglish

Related product manuals