Operation 38
To import the programs and labels into the machine, follow the steps below:
7. Insert a USB stick into the USB port of the machine.
8. In the menu, go to Import/Export and import the data.
6.7.2.2 Functions
The built-in functions of the machine can be enabled or disabled by the owner under Settings.
See Changing the ACS Settings on page 25. The options of the various programs can then be
programmed.
6.7.2.3 Vacuum
During the cycle, the air is removed from the chamber until the set pressure has been reached
(sensor-controlled).
To set the Vacuum option, follow the steps below:
1. Press the cursor keys
and
and select the program Vacuum.
2. Press Enter to open the menu.
3. If Vacuum is not enabled, enable it. Press Enter and use the cursor keys
and
to turn ON
Vacuum. Press Enter.
4. Use the cursor keys
and
to go to the value for the Vacuum and press Enter.
5. Set the desired value using the cursor keys
and
and press Enter.
6. Press the cursor key
to return to the menu.
7. Close the lid to start vacuuming.
6.7.2.4 Vacuum+ (optional)
If a lot of air is trapped in the product, it may be desirable to extend the vacuuming time after the
maximum vacuum has been reached. This to allow entrapped air to escape from the product.
You can only set Vacuum+ if Vacuum has been set to the maximum (99.8%). To set the Vacuum+
option, follow the steps below:
1. Set the value of the Vacuum to the maximum (99.8%) as described in Vacuum on page 38.
2. Enable Vacuum+. Use the cursor keys
and
to go to the value for the Vacuum+ and press
Enter.
3. Set the desired value using the cursor keys
and
and press Enter.
4. Press the cursor key
to return to the menu.
5. Close the lid to start vacuuming.
6.7.2.5 Gas (optional)
For the protection of the product, it may be desirable to insert a gas into the packaging after
vacuuming. Optionally, the machine can be equipped with a gas flush system.
See Technical Data on page 60 for the connection details.
Never use a gas mixture containing more than 20% oxygen or other explosive gases. This
may cause life-threatening explosions.