Operation 39
The insertion of gas lowers the seal pressure. The minimum final pressure (after the
insertion of gas) must be 30% (300 mbar) to ensure proper sealing.
To set the Gas function, follow the steps below:
1. Press the cursor keys
and
and select the program Gas.
2. Press Enter to open the menu.
3. If Gas is not enabled, enable it. Press Enter and use the cursor keys
and
to turn ON Gas.
Press Enter.
4. Use the cursor keys
and
to go to the value for Gas and press Enter.
5. Set the desired value using the cursor keys
and
and press Enter.
6. Press the cursor key
to return to the menu.
7. Close the lid to start vacuuming.
6.7.2.6 Gas+ (optional)
The Gas+ option only applies if the machine is equipped with the gas option. For some products it
may be desirable to insert additional gas into the packaging to create a "balloon packaging". This
allows for a better protection of a fragile product. The recommended value for Gas+ is 0.7 seconds.
To set the Gas+ option, follow the steps below:
1. Set the value of Gas in accordance with Gas (optional) on page 38.
2. Enable Gas+. Use the cursor keys
and
to go to the value for Gas+ and press Enter.
3. Set the desired value using the cursor keys
and
and press Enter.
4. Press the cursor key
to return to the menu.
5. Close the lid to start vacuuming.
6.7.2.7 Liquid Control (optional)
The Liquid Control option can be enabled or disabled for each program. If the product reaches the
boiling point before the set vacuum is reached, the machine will proceed to the next step of the
cycle.
To set the Liquid Control option, follow the steps below:
1. Press the cursor keys
and
and select the program Liquid Control.
2. Press Enter to open the menu.
3. If Liquid Control is not enabled, enable it. Press Enter and use the cursor keys
and
to turn
ON Liquid Control. Press Enter.
4. Use the cursor keys
and
to go to the value for Liquid Control and press Enter.
5. Set the desired value using the cursor keys
and
and press Enter.
6. Press the cursor key
to return to the menu.
7. Close the lid to start vacuuming.
The Liquid Control function prevents excessive fluid from being drawn out of the product. This
means that if the product reaches the boiling point, the machine will proceed to the next step of the
cycle. Depending on the moisture content, the manner in which moisture is bound, the available
surface for evaporation and the temperature, the end vacuum percentage might be limited and