42 INSTRUMENT SETUP
Figure 33
Security Button Location
5. Verify each option and set as necessary.Three pages must be verified
(Figure 34). Use the Up/Down Arrow keys (0 or 5) to select functions
and the Left/Right Arrow keys (1 or 3) to set each function to the
appropriate setting. Options include:
DISPLAY AND OUTPUT TEST WEIGHT: Enables/disables (YES/
NO) approximate grain test weight to display and print.
DISPLAY AND OUTPUT TEMPERATURE: Enables/disables
(YES/NO) grain temperature to display and print.
DISPLAY OUT-OF-LIMITS RESULT: Error messages flash on the
display each time tested grain parameters exceed the normal range
of that particular grain. If enabled, three standard parameters
display – moisture, grain temperature, and approximate grain test
weight. Each measured parameter value appears next to its
respective legend on the display. The display out-of-limit options
selected below establish whether or not the enabled values appear
on the display. Eight separate settings are available for suppressing
the enabled grain parameters.
OUTPUT OUT-OF-LIMITS RESULT: If enabled, three standard
parameters are printed – moisture, grain temperature, and
approximate grain test weight. Each measured parameter value
appears next to its respective legend on the printout. The output
out-of-limit options selected establish whether or not the enabled
values print. These choices are identical to the display out-of-limits
conditions above and are selected in a similar fashion.
SETTINGS:
1. YES - Enabled readings display for all out-of-limit conditions.
2. NO - Enabled readings do not display for any out-of-limit
condition.
3. M - Enabled readings display if moisture is out-of- limits but do
not display if either weight and/or temperature is out-of-limits.
4. W - Enabled readings display if weight is out-of-limits but do
not display if either moisture and/or temperature is
out-of-limits.
5. T - Enabled readings display if temperature is out-of-limits but
Security
Button
5
0
&
1
3
&
Up/Down Arrow Keys
Left/Right Arrow Keys

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dickey-John gac 2100 blue and is the answer not in the manual?

Dickey-John gac 2100 blue Specifications

General IconGeneral
BrandDickey-John
Modelgac 2100 blue
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals