- 29 -
DI-80 USER MANUAL
1.10.2.2 Counting Mode
For example: Accumulate 10000pcs of PLU 123 by key-in, 5kg of PLU 5 by weighing, 60000pcs of PLU 1 by key-in and
deducts 1kg of PLU 5 by Weighing.
OPERATION KEY DISPLAY
¼0»
NET
kg
0. 0 0 0
2. 0000 0
T
Pcs
1. At Counting Mode, enter the
existing PLU Number by
numeric key (Ex. 123) and
press [PLU] key.
10000
T
2. Enter the knowing Quantity
for the product (Ex.
10000Pcs).
Max. 9999999 can be
entering.
NET
Pcs
tot A L
Q U A N T I T Y 1 0 0 0 0
T T
3. Press [+] key.
Memory lamp light up.
Build-in Printer will start
printing if it connected and
label also be issue if machine
connect to Barcode Printer.
Refer to Note 1.
¼0»
NET
kg
0. 0 0 0
0. 1000 0
T T
Pcs
4. Press [5] and [PLU] key to
called up PLU 5.
Auto exit from Add. Mode
can be set at SPEC 32 bit 1.
NET
kg
5. 0 0 0
2. 0000 5 0000
T
T T
Pcs
5. Place the product on the
platter (Ex. 5kg).
Re-computing lamp light up.
Note 1: Label issue for Barcode Printer or Data send to PC only when [PRINT] key is depressed can be set at SPEC 19 bit 0.