AT commands Special commands
XBee® SX 868 RF Module User Guide
113
Special commands
The following commands are special commands.
AC (Apply Changes)
This command applies to the XBee SX 868 RF Module.
Immediately applies new settings without exiting Command mode.
Parameter range
N/A
Default
N/A
FR (Software Reset)
This command applies to the XBee SX 868 RF Module.
Resets the device. The device responds immediately with an OK and performs a reset 100 ms later.
If you issue FR while the device is in Command Mode, the reset effectively exits Command mode.
Parameter range
N/A
Default
N/A
RE (Restore Defaults)
This command applies to the XBee SX 868 RF Module.
Restore device parameters to factory defaults.
Parameter range
N/A
Default
N/A
WR (Write)
This command applies to the XBee SX 868 RF Module.
Writes parameter values to non-volatile memory so that parameter modifications persist through
subsequent resets.
Note Once you issue a WR command, do not send any additional characters to the device until after
you receive the OK response.
Parameter range
N/A