AT commands Firmware commands
XBee® SX 868 RF Module User Guide
157
Default
0x64 (10 seconds)
CN (Exit Command Mode)
This command applies to the XBee SX 868 RF Module.
Immediately exits Command Mode and applies pending changes.
Parameter range
N/A
Default
N/A
GT (Guard Times)
This command applies to the XBee SX 868 RF Module.
Set the required period of silence before and after the command sequence characters of the
Command mode sequence (GT + CC + GT). The period of silence prevents inadvertently entering
Command mode.
Parameter range
0x2 - 0x95C (x 1 ms)
Default
0x3E8 (one second)
Firmware commands
The following AT commands are firmware commands.
VL (Version Long)
This command applies to the XBee SX 868 RF Module.
Shows detailed version information including the application build date and time.
Parameter range
[read-only]
Default
N/A
VR (Firmware Version)
This command applies to the XBee SX 868 RF Module.
Reads the firmware version on a device.
Parameter range
0 - 0xFFFFFFFF [read-only]