AT commands Serial interfacing commands
XBee® SX 868 RF Module User Guide
131
Parameter Description
0x01 Even parity
0x02 Odd parity
Parameter Description
0 No parity
1 Even parity
2 Odd parity
Default
0x00
SB (Stop Bits)
This command applies to the XBee SX 868 RF Module.
Sets or displays the number of stop bits for UART communications.
Parameter range
0 - 1
Parameter Configuration
0 One stop bit
1 Two stop bits
Default
0
RO (Packetization Timeout)
This command applies to the XBee SX 868 RF Module.
Set or read the number of character times of inter-character silence required before transmission
begins when operating in Transparent mode.
Set RO to 0 to transmit characters as they arrive instead of buffering them into one RF packet.
Parameter range
0 - 0xFF (x character times)
Default
3
FT (Flow Control Threshold)
This command applies to the XBee SX 868 RF Module.
Set or display the flow control threshold.