EasyManua.ls Logo

Digi XBee SX 868 - CE (Node Messaging Options); C8 (Compatibility Options)

Digi XBee SX 868
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AT commands Network commands
XBee® SX 868 RF Module User Guide
120
CE (Node Messaging Options)
This command applies to the XBee SX 868 RF Module.
The routing and messaging mode bit field of the device.
A routing device repeats broadcasts. Indirect Messaging Coordinators do not transmit point-to-
multipoint unicasts until an end device requests them. Setting a device as an end device causes it to
regularly send polls to its Indirect Messaging Coordinator. Nodes can also be configured to route, or
not route, multi-hop packets.
Parameter range
0 - 6
Parameter Description Routes packets
0 Standard router Yes
1 Indirect message coordinator Yes
2 Non-routing device No
3 Non-routing coordinator No
4 Indirect message poller Yes
5 N/A N/A
6 Non-routing poller No
Default
0
C8 (Compatibility Options)
This command applies to the XBee SX 868 RF Module.
Sets or displays the operational compatibility with older versions of the firmware.
Parameter range
4
Bit field:
Bit Meaning Setting Description
2 Encryption
compatibility
0
When encryption is enabled, AES Counter mode is used with a
256-bit key.
1
When encryption is enabled AES ECB mode is used with a 128-bit
key. This bit must be set when using encryption with versions of
the firmware prior to 9009. It may be used in all circumstances if
set consistently throughout the network, but it disables the more
secure counter mode encryption.
All other bits should be 0 for future compatibility.