AT commands I/O settings commands
XBee® SX 868 RF Module User Guide
135
Parameter Description
0 Disabled
1 N/A
2 ADC
3 Digital input
4 Digital output, low
5 Digital output, high
Default
0
D4 (DIO4)
This command applies to the XBee SX 868 RF Module.
Sets or displays the DIO4 configuration (pin 24).
Parameter range
0, 3 - 5
Parameter Description
0 Disabled
1 N/A
2 N/A
3 Digital input
4 Digital output, low
5 Digital output, high
Default
0
D5 (DIO5/ASSOCIATED_INDICATOR)
This command applies to the XBee SX 868 RF Module.
Sets or displays the DIO5/AD5/ASSOCIATED_INDICATOR configuration (pin 28).
Parameter range
0, 1, 3 - 5