149
Specifies how long pin D3 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
T4 (D4 Output Timeout)
This command applies to the XBee SX 868 RF Module.
Specifies how long pin D4 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
T5 (D5 Output Timeout)
This command applies to the XBee SX 868 RF Module.
Specifies how long pin D5 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
T6 (D6 Output Timeout)
This command applies to the XBee SX 868 RF Module.
Specifies how long pin D6 holds a given value before it reverts to configured value. If set to 0, there is
no timeout.
Parameter range
0 - 0x1770 (x 100 ms)
Default
0
T7 (D7 Output Timeout)
This command applies to the XBee SX 868 RF Module.