AT commands Addressing commands
XBee® SX 868 RF Module User Guide
125
Option Description
Option Description
0x01
Append the DD (Digi Device Identifier) value to ND responses or API node identification
frames.
0x02
Local device sends ND response frame when the ND is issued.
Default
0x0
CI (Cluster ID)
This command applies to the XBee SX 868 RF Module.
The application layer cluster ID value. The device uses this value as the cluster ID for all data
transmissions.
Parameter range
0 - 0xFFFF
Default
0x11
DE (Destination Endpoint)
This command applies to the XBee SX 868 RF Module.
Sets or displays the application layer destination ID value. The value is used as the destination
endpoint for all data transmissions. The default value (0xE8) is the Digi data endpoint.
Parameter range
0 - 0xFF
Default
0xE8
SE (Source Endpoint)
This command applies to the XBee SX 868 RF Module.
Sets or displays the application layer source endpoint value. The value is used as the source endpoint
for all data transmissions. The default value (0xE8) is the Digi data endpoint.
This command only affects outgoing transmissions in transparent mode (AP = 0).
0xE8 is the Digi data endpoint used for outgoing data transmissions.
0xE6 is the Digi device object endpoint used for configuration and commands.
Parameter range
0 - 0xFF
Default
0xE8