AT commands Serial interfacing commands
XBee® SX 868 RF Module User Guide
130
parameter to vary from the sent parameter. Sending ATBD without an associated parameter value
returns the value actually stored in the device’s BD register.
The following table provides the parameters sent versus the parameters stored.
BD parameter sent (HEX) Interface data rate (b/s) BD parameter stored (HEX)
0 1200 0
4 19,200 4
7 115,200 7
1C200 115,200 1B207
Parameter ranges
0 - 8 (standard rates)
0x100 to 0x1C9468 (non-standard rates)
Parameter Configuration (b/s)
0 1200
1 2400
2 4800
3 9600
4 19200
5 38400
6 57600
7 115200
8 230400
Default
3
NB (Parity)
This command applies to the XBee SX 868 RF Module.
Set or read the serial parity settings for UART communications.
Parameter range
0x00 - 0x02
Parameter Description
0x00 No parity