AT commands I/O settings commands
XBee® SX 868 RF Module User Guide
133
I/O settings commands
The following AT commands are I/O settings commands.
CB (Commissioning Pushbutton)
This command applies to the XBee SX 868 RF Module.
Use CB to simulate commissioning pushbutton presses in software.
Set the parameter value to the number of button presses that you want to simulate. For example,
send CB1 to perform the action of pressing the Commissioning Pushbutton once.
See The Commissioning Pushbutton.
See Commissioning pushbutton.
Parameter range
0 - 4
Default
N/A
D0 (DIO0/AD0)
This command applies to the XBee SX 868 RF Module.
Sets or displays the DIO0/AD0 configuration (pin 33).
Parameter range
0 - 5
Parameter Description
0 Disabled
1 Commissioning Pushbutton
2 ADC
3 Digital input
4 Digital output, low
5 Digital output, high
Default
1
D1 (DIO1/AD1)
This command applies to the XBee SX 868 RF Module.
Sets or displays the DIO1/AD1 configuration (pin 32).
Parameter range
0, 2 - 5