Frame descriptions Remote AT Command Response- 0x97
XBee® SX 868 RF Module User Guide
200
Examples
Each example is written without escapes (AP = 1) and all bytes are represented in hex format. For
brevity, the start delimiter, length, and checksum fields have been excluded.
Set remote command parameter
Host set the NI string ofa remote device to "Remote" using aRemote AT Command Request - 0x17.
The corresponding 0x97 Remote AT Command Responsewith a matching Frame ID is emitted as a
response:
7E 00 0F 97 27 00 13 A2 00 12 34 56 78 12 7E 4E 49 00 51
Frame
type Frame ID
64-bit
source Reserved
AT
command
Command
Status Command data
0x97 0x27 0x0013A200
12345678
0x127E 0x4E49 0x00 (omitted)
Response Matches
request
Unused
"NI" Success Parameter
changes return
no data
Transmission failure
Host queued the the PAN ID change of a remote device using aRemote AT Command Request - 0x17.
Due to existing network congestion, the host will retry any failed attempts.
The corresponding 0x97 Remote AT Command Responsewith a matching Frame ID is emitted as a
response:
7E 00 0F 97 27 00 13 A2 00 12 34 56 78 FF FE 49 44 04 EA
Frame
type Frame ID
64-bit
source Reserved
AT
command
Command
Status
Command
data
0x97 0x27 0x0013A200
12345678
0xFFFE 0x4944 0x04 (omitted)
Response Matches
request
Unused
"ID" Transmission
failure
Parameter
changes return
no data
Query remote command parameter
Query the temperature of a remote device—TP (Temperature).
The corresponding 0x97 Remote AT Command Response with a matching Frame ID is emitted with the
temperature value as a response:
7E 00 11 97 27 00 13 A2 00 12 34 56 78 FF FE 54 50 00 00 2F A8