AT commands Firmware commands
XBee® SX 868 RF Module User Guide
158
Default
Set in firmware
HV (Hardware Version)
This command applies to the XBee SX 868 RF Module.
Display the hardware version number of the device.
Parameter range
0 - 0xFFFF [read-only]
Default
Set in firmware
HS (Hardware Series)
This command applies to the XBee SX 868 RF Module.
Read the device's hardware series number.
Parameter range
0 - 0xFFFF [read-only]
Default
Set in the firmware
DD (Device Type Identifier)
This command applies to the XBee SX 868 RF Module.
Stores the Digi device type identifier value. Use this value to differentiate between multiple XBee
devices.
Parameter range
0 - 0xFFFFFFFF
Default
0x110000
NP (Maximum Packet Payload Bytes)
This command applies to the XBee SX 868 RF Module.
Reads the maximum number of RF payload bytes that you can send in a transmission.
Parameter range
0 - 0xFFFF (bytes) [read-only]
Default
0x100