AT commands Serial interfacing commands
XBee® SX 868 RF Module User Guide
132
The device de-asserts CTS and/or send XOFF when FT bytes are in the UART receive buffer. It re-
asserts CTS when less than FT-16 bytes are in the UART receive buffer.
Parameter range
0x1A - 0x166 bytes
Default
0x11D
AP (API Mode)
This command applies to the XBee SX 868 RF Module.
Sets or reads the UART APImode.
Parameter range
0 - 2
The following settings are allowed:
Parameter Description
0
Transparent mode, API mode is off. All UART input and output is raw data and the
device uses the RO parameter to delineate packets.
1 API Mode Without Escapes. The device packetizes all UART input and output data in
API format, without escape sequences.
2 API Mode With Escapes. The device is in API mode and inserts escaped sequences to
allow for control characters. The device passes XON, XOFF, Escape, and the 0x7E
delimiter as data.
Default
0
AO (API Options)
This command applies to the XBee SX 868 RF Module.
The API data frame output format for RF packets received.
Parameter range
0, 1
Parameter Description
0 API Rx Indicator - 0x90, this is for standard data frames.
1 API Explicit Rx Indicator - 0x91, this is for Explicit Addressing data frames.
Default
0