AT commands I/O settings commands
XBee® SX 868 RF Module User Guide
138
Parameter Description
0 Disabled
1
ON/SLEEP output
2 N/A
3 Digital input
4 Digital output, low
5 Digital output, high
6 Synchronous pulse output
Default
1
P0 (DIO10/RSSI/PWM0 Configuration)
This command applies to the XBee SX 868 RF Module.
Sets or displays the PWM0/RSSI/DIO10 configuration (pin 7).
Parameter range
0 - 5
Parameter Description
0 Disabled
1 RSSI PWM0 output
2 PWM0 output
3 Digital input
4 Digital output, low
5 Digital output, high
Default
1
P1 (DIO11/PWM1 Configuration)
This command applies to the XBee SX 868 RF Module.
Sets or displays the DIO11/PWM1 configuration (pin 8).
Parameter range
0 - 5