Frame descriptions Queue Local AT Command Request - 0x09
XBee® SX 868 RF Module User Guide
170
Queue setting local command parameter
Set the UART baud rate to 115200, but do not apply changes immediately.
The device will continue to operate at the current baud rate until the change is applied with a
subsequent AC command.
The correspondingLocal AT Command Response - 0x88with a matching Frame ID will indicate
whether the parameter change succeeded.
7E 00 05 09 53 42 44 07 16
Frame type Frame ID AT command Parameter value
0x09 0x53 0x4244 0x07
Request Matches response "BD" 7 = 115200 baud
Query local command parameter
Query the temperature of the module (TP command).
The corresponding Local AT Command Response - 0x88frame with a matching Frame ID will return
the temperature value.
7E 00 04 09 17 54 50 3B
Frame type Frame ID AT command Parameter value
0x09 0x17 0x5450 (omitted)
Request Matches response "TP" Query the parameter