Frame descriptions Local AT Command Response - 0x88
XBee® SX 868 RF Module User Guide
182
Set local command parameter
Host set the NI string of the local device to "End Device" using a 0x08 request frame.
The corresponding Local AT Command Response - 0x88with a matching Frame ID is emitted as a
response:
7E 00 05 88 01 4E 49 00 DF
Frame
type Frame ID
AT
command
Command
Status Command data
0x88 0xA1 0x4E49 0x00 (omitted)
Response Matches
request
"NI" Success Parameter changes return no
data
Query local command parameter
Host queries the temperature of the local device—TP command—using a 0x08 request frame.
The corresponding Local AT Command Response - 0x88with a matching Frame ID is emitted with the
temperature value as a response:
7E 00 07 88 01 54 50 00 FF FE D5
Frame type Frame ID AT command Command Status Command data
0x88 0x17 0x5450 0x00 0xFFFE
Response Matches request "TP" Success -2 °C

Table of Contents