20
EN
IP2163EN
7.6.1 Additional BA level parameters that can be configured
(available with
enabled)
Display Description
DT - Adjustment of obstacle recognition time. [s/100]
10 - Minimum
60 - Maximum
NOTE:
the parameter is adjusted in hundredths of a second.
40
MP - Start at maximum power
ON - During start-up it increases the thrust on obsta-
cles to maximum.
OFF - During start-up the thrust on obstacles is that ad-
justed by -
ST - Adjustment of start time. [s]
0.5 - Minimum
3.0 - Maximum
2.0
TA - Adjustment of acceleration time. [s]
0.5 - Minimum (start speed is 75% of - )
2.0 - Maximum
2.0
TD - Adjustment of deceleration time. [%]
10 - Minimum
99 - Maximum
75
OB
- Adjustment of deceleration distance during opening. [cm]
Indicates the distance from the end of the opening
stroke where the deceleration ramp begins.
05 - Minimum
99 - Maximum
NOTE: reduce the deceleration space if there is a se-
ries of quick vibrations (chattering) in heavy gates in-
stalled with a slight incline.
40
CB - Adjustment of deceleration distance during closing. [cm]
Indicates the distance from the end of the closing
stroke where the deceleration ramp begins.
05 - Minimum
99 - Maximum
NOTE: reduce the deceleration space if there is a se-
ries of quick vibrations (chattering) in heavy gates in-
stalled with a slight incline.
40
PO - Adjustment of approach speed during opening.
[cm/s]
Indicates the speed from the end of the deceleration
ramp to the end of the stroke.
02 - Minimum
10 - Maximum
NOTE: gradually increase the approach speed if there is
a series of quick vibrations (chattering) in heavy gates
installed with a slight incline.
03
BA - Basic adjustment