• using keys ↑ and ↓ select the desired function
• press the ENTER key to confirm
7.10 Second level menu - EM (Energy Management)
Display Description
PV - Solar panel power supply (panels not supplied)
ON - Enabled
OF - Disabled
ES - Accessory power supply disconnection with
automation stopped or in stand-by “Energy Saving”
mode (RECOMMENDED FOR SOLAR PANEL SYSTEMS
- not supplied).
ON - Enabled (the LEDs are OFF, the red dot on the
right flashes every 5 s on the display, the flash-
ing light and the courtesy light are not oper-
ated).
OF - Disabled
The power supply disconnection mode is activated af-
ter 10 s with the gate closed or when the gate is closed
and automatic closing is not enabled or when a 1-9 -
STOP command intervenes.
The automation resumes normal operation after a
command received from the radio card (ZENRS-ZE-
NPRS) or after activation of a contact (for example, key
selector switch) connected between G3-G1.
WARNING:
- The GOPAV safety devices are not compatible with
this selection. Only SOF safety devices can be used.
- If is enabled, parallel or interlocked systems
cannot be used.
- With enabled, some signals like those for the
maintenance alarm and flat batteries are not active.
- The USB output is not active with enabled.
- The operating hours counter is not active.
WARNING: depending on the type of automation and control panel, some menus may
not be available.
EM - Energy management